Structure
A 1-layer aluminum coated polyester tape screen is wrapped on a foamed PE insulation core in accordance with VDE 0207 Part 2 02YI1, with a thickness that meets the electrical properties, on a conductor made of copper wire. After the braided screen made of tinned copper wires is wrapped on it, a white PVC sheath in accordance with VDE 0207 Part 5
YM1 is covered.

Technical Information
Temperature in fixed conditions: -40 °C, +70 °C
Temperature in moving conditions: -5 °C, +50 °C

Areas of Use
Used as an indoor CATV distribution cable and connection cable in systems where low attenuation is required.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
A 1-layer aluminum-coated polyester tape screen is wrapped on a foamed PE insulation core in accordance with VDE 0207 Part 2 02YI1, with a thickness that meets the electrical properties, on a conductor made of copper wire. After the braided screen made of tinned copper wires is wrapped on it, a white LSOH sheath in accordance with IEC 60332-1 is covered.

Technical Information
Temperature in fixed conditions: -40 °C, +70 °C
Temperature in moving conditions: -5 °C, +50 °C

Areas of Use
Used as a CATV distribution cable in buildings and as a connection cable in systems where low attenuation is required.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
A 1-layer copper-coated polyester tape screen is wrapped on a foamed PE insulation core in accordance with VDE 0207 Part 2 02YI1, with a thickness that meets the electrical properties, on a conductor made of copper wire. After the braided screen made of copper wires is wrapped on it, a white PVC sheath in accordance with VDE 0207 Part 5 YM1 is covered.

Technical Information
Temperature in fixed conditions: -40 °C, +70 °C
Temperature in moving conditions: -5 °C, +50 °C

Areas of Use
Used as indoor CATV distribution cable and connection cable in systems where low attenuation is required.

Structure
A 1-layer copper-coated polyester tape screen is wrapped on a foamed PE insulation core in accordance with VDE 0207 Part 2 02YI1, with a thickness that meets the electrical properties, on a conductor made of copper wire. After the braided screen made of copper wires is wrapped on it, a white LSOH sheath in accordance with IEC 60332-1 is covered.

Technical Information
Temperature in fixed conditions: -40 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C

Areas of Use
Used as a CATV distribution cable in buildings and as a connection cable in systems where low attenuation is required.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
A 1-layer aluminum-coated polyester tape screen is wrapped on a foamed PE insulation core in accordance with VDE 0207 Part 2 02YI1, with a thickness that meets the electrical properties, on a conductor made of copper wire. After the braided screen made of tinned copper wires is wrapped on it, a black PVC sheath in accordance with VDE 0207 Part 5
YM1 is covered. There is a yellow line on both sides of the sheath surface.

Technical Information
Temperature in fixed conditions: -40 °C, +70 °C
Temperature in mobile conditions: -5 °C, +50 °C

Areas of Use
Used as indoor CATV and CTV distribution cable and as a connection cable in SATV (Satellite antenna) systems where low attenuation is required.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
A 1-layer aluminum coated polyester tape screen is wrapped on a foamed PE insulation core in accordance with VDE 0207 Part 2 02YI1, with a thickness that meets the electrical properties, on a conductor made of copper wire. After the braided screen made of tinned copper wires is wrapped on it, a black LSOH sheath in accordance with IEC 60332-1 is covered. There is a yellow line on both sides of the sheath surface.

Technical Information
Temperature in fixed conditions: -40 °C, +70 °C
Temperature in moving conditions: -5 °C, +50 °C

Areas of Use
Used as a connection cable in indoor CATV and CTV distribution cables and SATV (Satellite antenna) systems where low attenuation is required.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
A 1-layer copper-coated polyester tape screen is wrapped on a foamed PE insulation core in accordance with VDE 0207 Part 2 02YI1, with a thickness that meets the electrical properties, on a conductor made of copper wire. After the braided screen made of copper wires is wrapped on it, a black PVC sheath in accordance with VDE 0207 Part 5 YM1 is covered. There is a violet line on both sides of the sheath surface.

Technical Information
Temperature in fixed conditions: -40 °C, +70 °C
Temperature in moving conditions: -5 °C, +50 °C

Areas of Use
Used as indoor CATV and CTV distribution cable and as a connection cable in SATV (Satellite antenna) systems where low attenuation is required.

Structure
A 1-layer copper-coated polyester tape screen is wrapped on a foamed PE insulation core in accordance with VDE 0207 Part 2 02YI1, with a thickness that meets the electrical properties, on a conductor made of copper wire. After the braided screen made of copper wires is wrapped on it, a black IEC 60332-1-compliant sheath is covered.
There is a violet line on both sides of the sheath surface.

Technical Information
Temperature in fixed conditions: -40 °C, +70 °C
Temperature in moving conditions: -5 °C, +50 °C

Areas of Use
Used as a connection cable in indoor CATV and CTV distribution cables and SATV (Satellite antenna) systems where low attenuation is required.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Features and Benefits
• For use in both 19” and ETSI standard racks.
• Suitable for Single Circuit management (up to 4 fibres per
tray) or Single Element management (up to 12 fibres per
tray).
• Can accommodate up to 96 splices in a 19” rack, and up to
120 splices in an ETSI rack for cable to pigtail splicing.
• Can accommodate up to 144 splices in a 19” rack or ETSI
rack for cable to cable splicing.
• Modular upgradeable solution.
• Shelf pulls outwards to enable easy access to the splice
trays.
• Splice tray holders are available for crimp, heatshrink or
fiberlock (only with half of the capacity) splices.
• Compatible with the OAsys Modular Main Rack.
• Fully bend managed to 30mm minimum bend radius.

Technical Data
SSR-S-59CC (cable to cable)
• Max Number of splice trays: 19”: 40 (SC), 16 (SE)
ETSI: 40 (SC), 16 (SE)
• Max number of splices: 19”: 144, ETSI: 144
• Max number of transport tubes: 12 in Ø 3.5/5 mm
12 out Ø 3.5/5 mm
• Required space envelope (mm): 19”: (w) 440 x (d) 280 x (h) 133
ETSI: (w) 490 x (d) 280 x (h) 133
• Operating temperature: -20oC to + 60oC (5 to 95% RH)
• Material:-
• Metalwork: Mild Steel (painted grey RAL 7035)
• Plastics: PC ABS (grey RAL 7035)
• Packing Dimensions (mm): (w) 570 x (d) 350 x (h) 200
• Packed Weight (kg): 8.3 (ETSI) 6.9 (19”)
• Net weight (kg): 7.5 (ETSI) 6.1 (19”)
SSR-S-59 (cable to pigtails)
• Max Number of splice trays: 19”: 48 (SC), 20 (SE)
ETSI: 60 (SC), 24 (SE)
• Max number of pigtails: 19”: 96, ETSI: 120
• Max number of transport tubes: 12 in Ø 3.5/5 mm
12 out Ø 3.5/5 mm
• Required space envelope (mm): 19”: (w) 440 x (d) 280 x (h) 133
ETSI: (w) 490 x (d) 280 x (h) 133
• Operating temperature: -20oC to + 60oC (5 to 95% RH)
• Material:-
• Metalwork: Mild Steel (painted grey RAL 7035)
• Plastics: PC ABS (grey RAL 7035)
• Testing:-
• Optical: tested at 1310 nm and 1550 nm
• Dry heat: IEC 60068-2-2 test B
• Damp heat: IEC 60068-2-3
• Change of temperature: IEC 60068-2-14
• Vibration: IEC 60068-2-6
• Shock: IEC 60068-2-27

Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Features and Benefits
• For use in both 19” and ETSI standard racks.
• Provides management of fibres through patching.
• Shelf pulls outwards to enable easy access to the patching
modules.
• Modules hinge upwards to provide access to the module
below.
• The shelf can accommodate a variety of different connector
types.
• Supplied with 72 adapters pre-installed to save installation
time.
• Compatible with the OAsys Modular Main Rack.
• Fully bend managed to 30mm minimum bend radius.

Technical Data
• Max Number of Adapters: 72
• Required space envelope (mm): 19” – (w) 415 x (d) 280 x (h) 133.5
ETSI – (w) 495 x (d) 280 x (h) 133.5
• Operating temperature: -20oC to + 50oC (5 to 95% RH)
• Material:-
• Metalwork: Mild Steel
• Plastics: FR Polymer
• Finish:-
• Metalwork: Painted light grey (RAL 7035)
• Plastics: Grey
• Testing:-
• Optical: Tested at 1310nm and 1550nm
• Dry heat: BS EN 60068-2-2 Test Bb
• Damp heat: IEC 60068-2-3: 1969
• Change of temperature: IEC 60068-2-14: 1984
• Vibration: IEC 60068-2-6: 1995
• Shock: IEC 60068-2-27: 1987

Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Features and Benefits
• Provides management of fibres through Splicing and
Patching.
• Splicing and bare fibre excess storage is performed inside a
splice tray protected by a cover.
• Compatible with 19” and ETSI racks.
• Supplied with 72 Adapters and pigtails pre-installed onto
the splice trays ready for connection to cable fibres.
• The shelf can accommodate a variety of different connector
types.
• Shelf pulls outwards to enable easy access to the splice
trays.
• Modules hinge upwards to provide access to the module
below.
• compatible with the OAsys Modular Main Rack.
• Fully bend managed to 30mm minimum bend radius.

Technical Data
• Max number of Adapters: 72
• Max number of Splices: 72
• Required space envelope (mm): 19” – (w) 415 x (d) 280 x (h) 133.5
ETSI – (w) 495 x (d) 280 x (h) 133.5
• Operating temperature: -20oC to + 50oC (5 to 95% RH)
• Material:-
• Metalwork: Mild Steel
• Plastics: FR Polymer
• Finish:-
• Metalwork: Painted light grey (RAL 7035)
• Plastics: Grey
• Testing:-
• Optical: Tested at 1310nm and 1550nm
• Dry heat: BS EN 60068-2-2 Test Bb
• Damp heat: IEC 60068-2-3: 1969
• Change of temperature: IEC 60068-2-14: 1984
• Vibration: IEC 60068-2-6: 1995
• Shock: IEC 60068-2-27: 1987

Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Features and Benefits
• High density low cost compact design for up to 48 fibres.
• Compatible with SC, FC, E2000, LC, ST connecter types.
• Cables anchor on the rear of the unit using a cable anchor plate supplied.
• Unit manufactured from high strength fire retardant plastic to give a light
weight solution.
• Supplied either as an empty unit, in kit format (with pigtails and adapters
in a bag) for installer loading, or with the pigtails and adapters pre-installed
by Prysmian.
• All fibres are positively managed to a 30mm minimum bend radius.
• Shelf pivots out to for access to the splice tray and pigtail area.
• Shelf can be used as a patch only solution and allows excess cable lengths
to be stored.
• Stackable splice bay allows for easy upgrade of splicing capacity.
• The shelf offers the ability to terminate up to 2 cables and allows through
splicing of fibres.
• Compatible with Sirocco blown fibre cables using a Blown Fibre Manifold.
The manifold enables up to 6 blown fibre tubes to be routed to a single
shelf.
• Available in 2 colours – grey RAL 7035 and black.

Technical Data
• No of splice trays: 1
• Maximum fibre capacity 24 (ST, FC, E2000)
48 (SC, LC)
• Max. Cable Diameter (mm): 18
• Cable capacity: 2
• Required space envelope (mm): (w) 481 x (d) 230 x (h) 44
• Operating temperature: -20o
C to + 50o
C (5 to 95% RH)
• Material: High Impact Polystyrene (Fire Retardant)
• Colour: Light Grey RAL 7035 or Black
• Testing:
• Optical: Tested at 1310nm and 1550nm
• Dry heat: BS EN 60068-2-2 Test Bb
• Damp heat: IEC 68-2-3
• Change of temperature IEC 68-2-14
• Vibration: IEC 68-2-6
• Shock: IEC 68-2-27

Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Features and Benefits
• High density cost effective compact design for housing
connectorised splitters in racks or cabinets.
• Compatible with SC and LC connecter types.
• Dedicated input and output positions for the splitter legs.
• Unit manufactured from high strength fire retardant plastic to give
a light weight solution.
• Supplied with connectorised splitters pre-installed by Prysmian.
• All fibres are positively managed to a 30mm minimum bend radius.
• Shelf pivots out to enable access to the splitter storage area for
maintenance.
• Ideal for high density FTTH applications with Passive Optical
Networks (PON)
• Can be mounted in racks, wall cabinets and street-side cabinets

Technical Data
• Required space envelope (mm): (w) 481 x (d) 230 x (h) 44
• Operating temperature: -20oC to + 50oC (5 to 95% RH)
• Material: High Impact Polystyrene
• Colour Grey RAL 7035
• Testing:-
• Optical: Tested 1310nm,1550nm and 1625nm
• Vibration: IEC 60068-2-6: 1995
• Shock: IEC 60068-2-27: 1987

Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Features and Benefits
•Modular panel design enables easy capacity upgrades from 12 to 48
fibres.
• Very high splice and patch density of 48 fibres for SC and LC connector
types in 1U.
• High splice and patch density of 24 fibres for ST, FC and E2000
connector types in 1U.
• Suitable for installation into 19”/ ETSI / ANSI racks, wall mounted
cabinets and street-side cabinets.
• Splice and patch module pivots outwards for easy fibre access and
maintenance.
•The drop down front panel prevents accidental disconnection of patchcords and provides additional space for patchcord routing during
installations.
• All fibres are positively bend managed to a 30mm radius
• Supplied with a large cover label and front panel labels for easy
identification and data recording.
• Splice and patch bay is covered with a detachable lid (secured with two
screws) to protect the splices and pigtails once installed.
•The panel can be used for optical splitters and other passive devices in
alternative configurations. Please contact Prysmian for further
information.
• Can accommodate most cable types including blown fibre tube cables.
Note: for 48f 1U shelves a 2mm Patch-cord size should be used.

Technical Data
• Max number of terminations 48 for SC or LC connectors
24 for FC, ST and E2000 connectors
• Max number of patchcords out: 48 with 2mm diameter patch cords
• Max Cable Diameter: 14mm
• Required space envelope (mm): (w) 480 x (d) 245 x (h) 44.5
• Operating temperature: -20oC to + 60oC (5 to 93% RH)
• Material:-
• Metalwork: Mild Steel
• Plastics: High Impact Polystyrene
• Finish:-
• Metalwork: Painted light grey RAL 7035
• Plastics: Light Grey RAL 7035
• Testing:-
• Optical: Tested at 1310nm,1550nm and 1625nm
• Dry heat: BS EN 60068-2-2 Test Bb
• Damp heat: IEC 60068-2-3: 1969
• Change of temperature: IEC 60068-2-14: 1984
• Vibration: IEC 60068-2-6: 1995
• Shock: IEC 60068-2-27: 1987

Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Features and Benefits
ƒ Modular system for installation into 19” / ETSI / ANSI racks, street-side
cabinets and wall mounted cabinets.
ƒ The sub-rack can be supplied fully configured or modules can be supplied
empty for upgrading at a later date.
ƒ Chassis are available in 1U, 2U and 3U options are supplied front
mounted as standard. Rear mounting brackets are available as an option.
ƒ Fibres are actively managed to minimum bend diameters throughout the
Splicing and Patching, Patching only, Splicing only, Patchcord Storage and
Splitter Modules.
ƒ Splicing and bare fibre excess storage is performed inside a tray
protected by a cover to prevent any accidental damage when open &
closing the shelves.
ƒ Modules pivot outwards for easy access.
ƒ Cables are completely protected from entry to exit of the panel.
ƒ Optical devices (i.e. Splitters & WDM’s) can be mounted within the
modules. Please contact Prysmian to discuss your requirements)
ƒ Wall mount 19” and ETSI cabinets are also available. Please contact
Prysmian for further details.
ƒ Modules have drop down fronts for easier patchcord routing, enclosing
patch-cords, and protecting adapters.
ƒ 2 large labelling areas provided for identification recording per module.

Technical Data
• Max number of splices
• 1U 48 ( SC & LC), 24 ( FC, ST & E2000)
• 2U 96 (SC & LC), 48 (FC, ST & E2000)
• 3U 144 (SC & LC), 72 (FC, ST & E2000)
• Max number of output patchcords:
• 1U 48 with 2mm diameter patch cords
• 2U 96 with 2mm diameter patch cords
• 3U 144 with 2mm diameter patch cords
• Max Cable Diameter (mm): 14
• Required space envelope (mm):
• 1U: (w) 480 x (d) 245 x (h) 44.5
• 2U (w) 480 x (d) 245 x (h) 89.0
• 3U (w) 480 x (d) 245 x (h) 133.5
• Operating temperature: -20oC to + 60oC (5 to 93% RH)
• Material:-
• Metalwork: Mild Steel
• Plastics: High Impact Polystyrene
• Finish:-
• Metalwork: Painted light grey RAL 7035
• Plastics: Light Grey RAL 7035
• Testing:-
• Optical: Tested at 1310nm,1550nm and 1625nm
• Dry heat: BS EN 60068-2-2 Test Bb
• Damp heat: IEC 60068-2-3: 1969
• Change of temperature: IEC 60068-2-14: 1984
• Vibration: IEC 60068-2-6: 1995
• Shock: IEC 60068-2-27: 1987

Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Features and Benefits
• Suitable for installation into 19”/ ETSI / ANSI racks, wall mounted
cabinets and street-side cabinets.
• The shelf has a capacity of up to 48 fibre splices.
• The shelf is supplied with splice protector holders for 2.2mm heat
shrink splice protectors. Crimp splice protectors can also be
accommodated by using crimp splice protector holders. Refer to
additional items.
• Can accommodate most cable types including blown fibre tube cables.
• Splice module pivots outwards for easy fibre access and maintenance.
• The shelf can be used for optical splitters and other passive devices in
alternative configurations. Please contact Prysmian for further
information.
• The drop down front panel prevents accidental disconnection of fibre
routing tubes during installations.
• All fibres are positively bend managed to a 30mm radius
• Supplied with a large cover label and front panel labels for easy
identification and data recording.
• Splice bay is covered with a detachable lid (secured with two screws)
to protect the fibres once installed.

Technical Data
• Max number of splices 48
• Splice protectors accommodated: 2.2mm heat shrink or crimp
• Max number of output patchcords: 48 with 2mm diameter patch cords
• Max Cable Diameter: 14mm
• Required space envelope (mm): (w) 480 x (d) 245 x (h) 44.5
• Operating temperature: -20oC to + 60oC (5 to 93% RH)
• Material:-
• Metalwork: Mild Steel
• Plastics: High Impact Polystyrene
• Finish:-
• Metalwork: Painted light grey RAL 7035
• Plastics: Light Grey RAL 7035
• Testing:-
• Optical: Tested at 1310nm,1550nm and 1625nm
• Dry heat: BS EN 60068-2-2 Test Bb
• Damp heat: IEC 60068-2-3: 1969
• Change of temperature: IEC 60068-2-14: 1984
• Vibration: IEC 60068-2-6: 1995
• Shock: IEC 60068-2-27: 1987