Inner conductor: solid copper wire, bare, diameter 1.6 mm
Insulation: Foam-PE, diameter 7.3 mm
Outer conductor: Al-PET-Al-foil under tinned copper braid, diameter 8.2 mm
Sheath: FRNC, diameter 10.3 mm green, RAL 6018
Printing;
for FRNC: DRAKA COMTEQ – 1.6/7.3 AF – 75  ± 1% – HDTV FRNC
for PVC: DRAKA COMTEQ – 1.6/7.3 AF – 75  ± 1% – HDTV
for PUR: DRAKA COMTEQ – 1.6/7.3 AF – 75  ± 1% – HDTV PUR

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, multi-wire or compressed multi-wire copper conductor, special XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, rubber-filled, copper wire braided, ship cables that continue their function for 180 minutes under fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– FE (Current Conduction) Test: IEC 60331-21

Areas of Use
They are used as energy and control cables in ships and all kinds of marine vehicles, on decks, in dry, wet and steamy areas, in fixed installations where mechanical and electrical protection is required, in security, alarm and other critical systems. They are manufactured to continue their functions under fire.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Features and Benefits
• Modular panel design enables easy capacity upgrades from 12 to 48 fibres.
• Excellent optical fibre cord management, minimum cable and patchcords
movement.
• Patchcords exit the unit from the front of the shelf.
• Pull out drawer for easy access for splicing and maintenance.
• Can accommodate up to 24 duplex adapters of ST, FC, SC, E2000 and quad
LC type.
• Can accommodate up to 3 splice trays each able to accommodate up to 24
splices.
• Suitable for installation into 19”/ ETSI racks, wall mounted cabinets and
street-side cabinets.
• Manufactured from steel painted light grey Ral 7035
• Supplied either as an empty unit, in kit format (with pigtails and adapters
in a bag) for installer loading.
• All fibres are positively managed to a 30mm minimum bend radius.
• Shelf has a pull out drawer for access to the splice tray and pigtail area.
• Cables enter the unit from the rear. Up to 4 cables can of up to
21mm in diameter can be accommodated.
•The panel can be used for optical splitters and other passive devices in
alternative configurations. Please contact Prysmian for further information.

Technical Data :
• Max number of terminations: 24 with FC, ST, 48 E2000,SC and 96 with LC
• Connector types: FC, ST, E2000, SC or LC
• Max number of cable in: 4
• Max cable diameter: 21mm
• Max number of patchcords out: 48 with FC, ST, E2000 or SC, 96 with LC
• Max number of splice trays: 2
• Splice tray capacity: 24 splices each
• Required space envelope (mm): (w) 482 x (d) 300 x (h) 45
• Operating temperature: -10oC to + 50oC (5 to 90% RH)
• Material: Steel
• Finish: Painted light grey RAL 7035

Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Structure
Single or multi-core, multi-wire or compressed multi-wire copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, rubber-filled, copper wire braided ship cables that do not create a dense smoke layer in the event of a fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Places of Use
They are used as energy and control cables in fixed installations where mechanical and electrical protection is required on ships and marine vehicles, in security, alarm and other critical systems.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, finely stranded copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, non-smoking rubber-filled, copper wire braided ship cables.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Areas of Use
They are used as energy and control cables in fixed installations, security, alarm and other critical systems where mechanical and electrical protection is required on ships and marine vehicles.

Structure
Single or multi-core, fine multi-wire copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, ship cables that do not create dense smoke during fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Areas of Use
They are used as energy and control cables in fixed installations, under decks, dry, wet and steamy areas on ships and all kinds of marine vehicles.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, multi-wire copper conductor, special halogen-free XLPE insulation, special synthetic outer sheath, flame retardant, halogen-free, ship cables that do not create dense smoke during fire.

Technical Information
– Manufactured in accordance with IEC 60092-350/353.
– Minimum allowed operating temperature: -15 ºC
– Maximum allowed operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-3-22 Cat.A
– Suitable for use in oily environments.

Areas of Use
They are used as energy and control cables in fixed installations, under decks, dry, wet and steamy areas on ships and all kinds of marine vehicles.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Features and Benefits
• Modular panel design enables easy capacity upgrades from 12 to 96 fibres.
• Excellent optical fibre cord management, minimum cable and patchcords
movement.
• Patchcords exit the unit from the front of the shelf.
• Pull out drawer for easy access for splicing and maintenance.
• Can accommodate up to 48 adapters of ST, FC, SC, E2000 and duplex LC
type.
• Can accommodate up to 4 splice trays each able to accommodate up to 24
splices.
• Suitable for installation into 19”/ ETSI racks, wall mounted cabinets and
street-side cabinets.
• Manufactured from steel painted light grey Ral 7035
• Supplied either as an empty unit, in kit format (with pigtails and adapters
in a bag) for installer loading.
• All fibres are positively managed to a 30mm minimum bend radius.
• Shelf has a pull out drawer for access to the splice tray and pigtail area.
• Cables enter the unit from the rear. Up to 4 cables can of up to
21mm in diameter can be accommodated.
•The panel can be used for optical splitters and other passive devices in
alternative configurations. Please contact Prysmian for further information.

Technical Data :
• Max number of terminations: 48 with FC, ST, E2000 or SC, 96 with LC
• Connector types: FC, ST, E2000, SC or LC
• Max number of cable in: 4
• Max cable diameter: 21mm
• Max number of patchcords out: 48 with FC, ST, E2000 or SC, 96 with LC
• Max number of splice trays: 2
• Splice tray capacity: 24 splices each
• Required space envelope (mm): (w) 482 x (d) 300 x (h) 89
• Operating temperature: -10oC to + 50oC (5 to 90% RH)
• Material: Steel
• Finish: Painted light grey RAL 7035

Ürün teknik özellik ve detayları için PDF ikonuna tıklayarak detayları görüntüleyebilir, dosyayı indirebilir veya istediğiniz adrese mail yolu ile ulaştırabilirsiniz.

Structure
Multi-core, multi-wire, copper conductor, special synthetic insulated, galvanized flat steel wire armored, special synthetic outer sheathed, flame retardant, halogen-free and non-smoking energy cables.

Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– Galvanized Flat Steel Wire Armored

Areas of Use
These cables are resistant to mechanical external effects thanks to the armor consisting of galvanized flat steel wires on them. They are used in places where mandatory safety precautions are taken against fire.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single or multi-core, single or multi-wire, copper conductor, three or four-core, special synthetic insulated, galvanized round steel wire armored, special synthetic outer sheathed, flame retardant, halogen-free and non-smoking energy cables. (Aluminum in single-core cables.)

Technical Information
– Manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Galvanized Round Steel Wire Armored

Areas of Use
These cables are resistant to mechanical external effects thanks to the armor consisting of galvanized round steel wires on them. They are used in places where there are mandatory safety precautions against fire.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, galvanized round steel wire armor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking during fire and continue to function for 180 minutes under flame according to IEC 60331-21. (Armor is aluminum in single-core cables.)

Technical Information
– They are manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21

Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, galvanized round steel wire armor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking during fire and continue to function for 180 minutes under flame according to IEC 60331-21. (Armor is aluminum in single-core cables.)

Technical Information
– They are manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21

Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, galvanized round steel wire armor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking during fire and continue to function for 180 minutes under flame according to IEC 60331-21. (Armor is aluminum in single-core cables.)

Technical Information
– They are manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21

Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single or multi-core, single or multi-wire copper conductor, special flame-resistant separator layer, special synthetic insulation, galvanized round steel wire armor, special synthetic outer sheath, flame-retardant, halogen-free, non-smoking during fire and continue to function for 180 minutes under flame according to IEC 60331-21. (Armor is aluminum in single-core cables.)

Technical Information
– They are manufactured in accordance with TS IEC 60502-1.
– Permissible operating temperature: 90 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Rigid
– LS (Low Smoke) Test: IEC 61034 -1/2
– Burning Droplet Test: IEC 60332-1-3
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2 and IEC 60332-3-24 Cat.C
– FE (Current Conduction) Test: IEC 60331-21

Areas of Use
These cables are used in indoor and outdoor areas such as schools, hospitals, meetings and shopping malls where there are mandatory safety precautions against fire.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

External Type Cable Headers for Three-Core Medium Voltage Cables