The central tube contains optical fibers and waterproof material, forming the cable core. To increase dielectric strength, glass yarn material is applied around the cable core. To protect the cable core from external factors, corrugated steel tape armor is applied, both sides of which are coated with copolymer material. Black LSOH sheath is applied on top of the armor.

Technical Information
– Temperature in fixed conditions: -30 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C
– Minimum Operating Temperature: -30 ºC
– Maximum Operating Temperature: 70 ºC
– Conductor Structure: Rigid
– Bending Radius: Min 15xD
– Lead-free

Areas of Use
These center tube, armored fiber optic cables are designed for in-duct or direct burial, indoor and outdoor environment cables.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. To increase dielectric strength, glass yarn material is applied around the cable core. To protect the cable core from external factors, corrugated steel tape armor is applied, both sides of which are coated with copolymer material. Black LSOH sheath is applied on top of the armor.

Technical Information
– Temperature in fixed conditions: -30 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C

Areas of Use
These center tube, armored fiber optic cables are designed for indoor and outdoor use, in ducts or for direct burial.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. To increase dielectric strength, glass yarn material is applied around the cable core. To protect the cable core from external factors, corrugated steel tape armor is applied, both sides of which are coated with copolymer material. Black LSOH sheath is applied on top of the armor.

Technical Information
– Temperature in fixed conditions: -30 °C, +70 °C
– Temperature in moving conditions: -10 °C, +50 °C

Areas of Use
These center tube, armored fiber optic cables are designed for indoor and outdoor use, in ducts or for direct burial.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. To increase dielectric strength, glass yarn material is applied around the cable core. Black LSOH sheath is applied on the glass yarn material.

Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: 0 °C, +50 °C

Areas of Use
These center tube, LSOH, unarmored fiber optic cables are designed for use in indoor environments.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. To increase dielectric strength, glass yarn material is applied around the cable core. Black LSOH sheath is applied on the glass yarn material.

Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: 0 °C, +50 °C

Areas of Use
These center tube, LSOH, unarmored fiber optic cables are designed for use in indoor environments.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
The center tube contains the optical fibers and waterproof material, forming the cable core. To increase dielectric strength, glass yarn material is applied around the cable core. Black LSOH sheath is applied on the glass yarn material.

Technical Information
– Temperature in fixed conditions: -25 °C, +70 °C
– Temperature in moving conditions: 0 °C, +50 °C

Areas of Use
These center tube, LSOH, unarmored fiber optic cables are designed for use in indoor environments.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single-core, very thin and multi-wire, copper conductor, flame and oil resistant, rubber outer sheathed flexible welding cables.

Technical Information
– Manufactured in accordance with TS EN 50525-2-81.
– Permissible operating temperature: 85 ºC
– Maximum Short Circuit Temperature: 250 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.

Places of Use
They are used as power and connection cables in welding machines, in oily and hot environments under all kinds of weather conditions, both internally and externally.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, finely stranded, copper conductor, PROTODUR® (PVC) insulated, PROTODUR® (PVC) outer sheathed, flexible cables.

Technical Information
– Manufactured according to TS EN 50525-2-11.
– Permissible Operating Temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 1.5 kV

Areas of Use
They are used as mobile connection cables in closed and dry places where mechanical stresses are low.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, fine multi-wire, copper conductor rubber insulated, flame and oil resistant rubber outer sheathed cables.

Technical Information
– Manufactured in accordance with TS EN 50525-2-21.
– Permissible operating temperature: 60 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.

Areas of Use
They are used in humid places, kitchen appliances such as water heaters, electric stoves, portable workshop devices such as hand drills and hand lamps, places where mechanical effects are low, oily places. These cables are flame resistant according to IEC 60332-1-2.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, fine multi-wire, copper conductor, rubber insulated, flame and oil resistant rubber outer sheathed industrial type cables.

Technical Information
– Manufactured in accordance with TS EN 50525-2-21.
– Permissible operating temperature: 60 ºC
– Maximum Short Circuit Temperature: 200 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Suitable for use in oily environments.

Areas of Use
They are used in humid places, in kitchen appliances such as water heaters, electric stoves, portable workshop devices such as hand drills and hand lamps, and in places where mechanical effects are low.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single-core, finely stranded, copper conductor PROTODUR® (PVC) insulated flexible cables.

Technical Information
– Manufactured according to TS EN 50525-2-31.
– Permissible Operating Temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 2 kV-2.5 kV

Areas of Use
They are used in the internal installations of panels and electrical devices, under plaster or in pipes on plaster.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single-core, single or multi-wire, copper conductor PROTODUR® (PVC) insulated cables.

Technical Information
– Manufactured according to TS EN 50525-2-31.
– Permissible Operating Temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Rigid
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 2 kV-2.5 kV

Areas of Use
They are used in closed, dry places, fixed installations, distribution panels, under plaster and on plaster inside pipes, on hooks.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, finely stranded, copper conductor PROTODUR® (PVC) insulated, PROTODUR® (PVC) outer sheathed, flexible cables.

Technical Information
– Manufactured according to TS EN 50525-2-11.
– Permissible Operating Temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2
– Test Voltage (AC): 2 kV

Areas of Use
They are used in closed and dry places where mechanical stresses are present, in household appliances, in steamy and humid places.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, finely stranded, electrolytic copper conductor, PROTODUR® (PVC) insulated, core numbered, oil resistant, PROTODUR® (PVC) outer sheathed, flexible measurement and control cables.

Technical Information
– Manufactured in accordance with TS EN 50525-2-51.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 2 kV
– Suitable for use in oily environments.

Areas of Use
They are used as measurement and control cables in dry, damp and wet areas, in places where there is no high mechanical stress internally, in machines, mass production lines, control devices, computer systems.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Multi-core, finely stranded, electrolytic copper conductor, PROTODUR® (PVC) insulated, cores numbered, PROTODUR® (PVC) inner sheathed, tinned copper wire braid screened, oil resistant, PROTODUR® (PVC) outer sheathed, flexible measurement and control cables.

Technical Information
– Manufactured in accordance with TS EN 50525-2-51.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– FR (Flame Resistance) Test: IEC 60332-1-2
– Test Voltage (AC): 2 kV
– Suitable for use in oily environments.

Areas of Use
They are used as measurement and control cables in dry, damp and wet areas where the degree of protection against electromagnetic interference is required, in places where there is no high mechanical stress internally, in machines, mass production lines, control devices, computer systems.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file or send it to the address you want via e-mail.

Structure
Single-core, single-wire, multi-wire or fine multi-wire copper conductor, special synthetic insulation, flame retardant and halogen-free energy cables.

Technical Information
– Manufactured in accordance with TS EN 50525-3-31.
– Permissible operating temperature: 70 ºC
– Maximum Short Circuit Temperature: 160 ºC
– Conductor Structure: Flexible
– LS (Low Smoke) Test: IEC 61034 -1/2
– HF (Halogen Free) Test: IEC 60754 – 1/2
– FR (Flame Resistance) Test: IEC 60332-1-2
– CPR (Construction Materials Directive) Test: EN 60332-1-2

Places of Use
They are used as lighting and installation cables in dry spaces, switchgear facilities, distribution systems, and businesses.

For product technical specifications and details, you can view the details by clicking on the PDF icon, download the file, or send it to the address you want via e-mail.